Sinpo Medical 锐盛医疗科技

Best Quality And Service for Hospital Around the World
Product Detail
B-3000(LCD)
Detail

STANDARD FEATURES:

● Servo Control Mode: air temperature, skin temperature, humidity;

● Parameter Displaying: set temperature,air temperature, skin temperature, internal humidity,


oxygen,heat power rate;

● Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air & skin temperature


override,fan failure, system failure;

● >37℃Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;

● Hood with dual slope; 6 hand-ports;

● Bed mattress with X-ray cassette;

● RS-232 Output Connector (use for networksystem);

● IV poles;

● Monitoring shelf

● Protective guard rail;

● Storage cabinets.

OPTIONS:

● Height adjustable stand

● Double wall

● Humidity control system

● LCD display screen

● Oxygen control system

● Oxygen cylinder position holder

● Ventilator tube support


Specifications of hood

Mattressto Hood: 450 mm

Observation side of hood: Two incline

Operate port: 6 (2 Iris ports)

Tubing grommets: 4

Front access panel: 826×310 mm

Mattress Tray Size: 630×360 mm


Technical Specifications:    

Power requirement ≤400VA

Temperature control mode: Air and skin servo control

Air Temp Control Range: 20℃~37℃

Temperature override mode to: 20℃~39℃

Skin Temp Control Range: 30℃~37℃

Temperature override mode to: 30℃~38℃

Skin temp sensor accuracy: ≤0.3℃

Humidity display range: 5%RH~99%RH

Humidity control range: 35%RH~95%RH

Humidity control accuracy: ±10%RH

Oxygen control range:21% to 65%

Oxygen control accuracy(100% calibration): ±3%

Oxygen control accuracy(21% calibration): ±5%

Oxygen display accuracy: ±2%

Temperature fluctuation: ≤0.5℃

Mattress temperature uniformity: ≤0.8℃

Temperature rise time: ≤45 min

Noise level within hood environment: ≤50dB


Alarms  

Power failure alarm        

Fan failure alarm

Sensor failure alarm

High air temperature alarm: +3.0℃

Low airtemperature alarm: -3.0℃

High skin temperature alarm: +1.0℃

Low skin temperature alarm: -1.0℃

Over air temperature alarm: ≤38.0℃; ≤40.0℃

Over skin temperature alarm: ≤38.0℃; ≤39.0℃

System failure alarm  

Alarm silence function

Operational condition  

Environment temperature: +20℃~+30℃

Environment relative humidity: 5%~99%

Environment air velocity of flow: <0.3m/s


Others    

Infant bed tilt adjusting  ±10° step-less

Mattress tray Max. load  10kg

Transfusion pole Max. load   2kg

Cabinet Max. load  6kg



ericchang605@gmail.com
sinpomedical@gmail.com
24Hour Hotline
0086 571 8275 3109
0086 576 8990 3136
China
NO.108,Shixin North RD,Economic And Technological Development Zone, Xiaoshan District,Hangzhou City,Zhejiang Province-311215
website qrcode

Scan it

Bangladesh
Concept Tower,Room No.4D,3rd Floor,68-69 Green RD,Dhanmondi,Dhaka-1205
Login
Login
leave a message
back to the top